Case Studies · Mid Somerset

DS Electrical — Real Installations, Mid Somerset

How we approach each job, without naming clients. Three working examples covering commercial network, landlord portfolio EICRs and a Grade II Bath heritage rewire.

NAPIT
Approved 66245
CHAS
Accredited 158368
2391
City & Guilds
TrustMark
Government Endorsed
Part P
Building Regulations
BS 7671
18th Edition Compliant

These are reference installations carried out by DS Electrical Installations (SW) Ltd across Mid Somerset and Bath. We deliberately do not name clients, addresses or dates — the value is in the approach, the kit chosen, the survey, the staging, the certification. If your project shape matches one of these, the pattern travels.

Every install ends the same way: tested to BS 7671, NAPIT-certified, paperwork in your inbox, the board labelled and the customer shown how it all works. That's the shape of the job.

Twelve reference jobs

Pick the shape closest to yours

Managed PoE switch, patch panel and fibre tray inside a 27U comms cabinet
01 · Commercial

Commercial network infrastructure — Mid Somerset site

Survey, design and 3-day phased install. 8 access points, 24-port managed PoE, 27U cabinet, 96-port patch panel. Out-of-hours commissioning so the floor never stopped.

Read the case study →
Megger MFT insulation tester reading 908 megohm during EICR
02 · Landlord

Compliance reset — portfolio EICR + smoke alarm visit

12-property portfolio across Mid Somerset, rolling 14-day visit, per-circuit pricing, 8 satisfactory + 4 with C2 remediation. Smoke alarm upgrades in 2.

Read the case study →
Period brass lantern installed inside a Grade II Bath property
03 · Heritage

Grade II Bath rewire — without disturbing original features

4-bed terraced Bath property, conservation officer liaison, invisible cable routing, brass-finish accessory schedule, 9 working days, full RCBO board with AFDD bedroom + SPD.

Read the case study →
Commercial EV fleet charging bays installed at a Somerset depot
04 · Commercial EV

Commercial EV fleet charging — Somerset operator

Six 22 kW 3-phase Type 2 chargers, dynamic load management, OZEV Workplace Charging Scheme grant, 4 working days, BS 7671 cert + Part P notified.

Read the case study →
BS 5839-1 analogue addressable fire alarm detector at a Somerset primary school
05 · Education

Somerset primary school partial rewire

Six classrooms, fire-alarm panel cut-over, BS 5266 emergency lighting refresh, staged across two half-terms. RCBO Type A throughout, BS 5839-1 + Part P + DBS site team.

Read the case study →
Country pub front-of-house dimmable downlights and pendant lighting
06 · Hospitality

Country pub kitchen + bar fit-out near Bruton

3-phase commercial kitchen, twin 32 A induction hobs, walk-in cold room, dimmable FOH lighting, 7 kW car-park EV charger. 8 working days, ready for reopening night.

Read the case study →
Heritage Bath drawing room with brass period fittings and concealed cove lighting
07 · Heritage Lighting

Cinema downlight + concealed strip in a Grade-II Bath drawing room

Somerset listed Georgian townhouse near the Royal Crescent. 12 LED downlights, concealed cove-strip uplight, 3 dimming zones, brass plate switches, no surface trunking, 6 working days.

Read the case study →
Megger MFT insulation tester reading on a final circuit during a care-home EICR
08 · Care & Compliance

Care-home group EICR cycle — 4 South West sites

4-property care-home operator, 3-phase TP&N supplies, BS 7671 Amd 2 testing, BS 5839-1 fire-alarm and BS 5266 emergency-lighting cross-check, CQC-friendly compliance pack per site. From £800 per property.

Read the case study →
Open-plan kitchen-diner with even LED downlight wash from a 4x3 grid of fittings
09 · Domestic Lighting

Downlight retrofit — Bath BA2 ground-floor flat

Single-storey extension, pendant-only to 12 LED dimmable downlights on 2 zones. Click Scolmore Deco Plus chrome plates, 6+ year LED lifespan, single-day install, ready for the agent's photographer the next morning.

Read the case study →
Hypervolt 7 kW EV charger mounted above an off-street parking bay at a Bath two-flat conversion
10 · EV Charging

Dual EV chargers — Bath two-flat conversion

Two Hypervolt 7 kW chargers, two OZEV EVHS grants, separate MID sub-meters, Type A RCBO each, DNO-notified communal mains upgrade 60 A to 100 A. Five working days.

Read the case study →
Addressable BS 5839-1 fire alarm panel installed in a Grade-II Listed pub staff corridor
11 · Fire Alarm

BS 5839-1 fire alarm — Grade-II Listed pub near Bruton

Addressable Category L2 system in a Grade-II Listed coaching inn. Heritage-sensitive cable routes, FP200 throughout, FRS-ready handover, BS 5266 emergency-lighting cross-check. Six working days.

Read the case study →
Interior of a converted stone barn near Wells with exposed stone walls and concealed wiring
12 · Barn Conversion

Stone barn conversion full rewire near Wells

4-bed converted stone barn, 100 A intake, 2 RCBO consumer units (main + annexe), 32 A heat-pump circuit Type A RCBO, EV-ready socket plumbed, garden lighting, no surface trunking on stone. Twelve working days.

Read the case study →
About the figures. Numbers given on these pages (durations, port counts, property counts, AP counts, etc.) describe representative reference jobs. Your job will be priced on its own survey. All prices on the DS Electrical website and in our quotes are subject to VAT at the current rate (20%). DS Electrical Installations (SW) Ltd is VAT-registered (GB 429 0409 05).

Got a project that fits one of these shapes?

Send the brief. Survey first, fixed quote, no surprises. Mid Somerset & Bath only.

07889 334849
Get a Quote WhatsApp See the Gallery
Call Dan — 07889 334849
Call Dan07889 334849 WhatsApp Email