Bathroom circuits in Wells (BA5) — Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Local Wells electrician for bathroom circuits — Section 701 IP44+, RCD-protected, electric showers, heated towel rails, IP-rated lighting. NAPIT-certified. From £120 + VAT @ 20%.
Or WhatsApp: wa.me/447889334849
NAPIT
CHAS
City & GuildsBathroom circuits in Wells (BA5) — Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Local Wells electrician for bathroom circuits — Section 701 IP44+, RCD-protected, electric showers, heated towel rails, IP-rated lighting. NAPIT-certified. From £120 + VAT @ 20%.
Full service detail and the eight-circuit kitchen brief on our parent Bathroom Electrics page.
Wells is the smallest cathedral city in England — the historic core has tight stone-built bathrooms shoehorned into Georgian and Victorian terraces, where Section 701 zoning is genuinely tight. We measure every zone before specifying fittings.
Wells suburbs and surrounding villages mix modern estates with character properties — straightforward bathroom rewires alongside heritage work. We issue full Minor Works or EIC certs on every job.
Wells is local to our Glastonbury base — we cover Wells daily and can usually survey the same week.
Sister city pages: EICR in Wells · Rewires in Wells
Final price depends on access, cable routes, existing wiring and whether the room is being refurbed at the same time. Survey is free; written quote is fixed. Read the disclaimer below the cards before assuming.
Wells is 6 miles from our Glastonbury base — same-day for emergency isolations or shower failures, same-week for full bathroom rewires.
Single-circuit jobs (extractor, towel rail, shaver, mirror) are 1 day. A shower circuit replace is normally 1 day. A full bathroom rewire (extractor, lighting, shaver, towel rail, shower) is 2-3 days for first-fix and 1 day for second-fix after the tiling is in.
Section 701 of BS 7671 is the special-locations chapter for rooms with baths and showers. It defines Zones 0, 1 and 2 around the bath/shower and dictates IP rating and what fittings are permitted in each zone. Zone 0 is inside the bath itself (12V SELV only). Zone 1 is above the rim (IP65, 30mA RCD). Zone 2 is the area within 0.6m of zone 1 (IP44 minimum). Outside zones is 'general' but RCD protection is still required on every circuit serving the bathroom.
Free survey, fixed-price written quote, full BS 7671 Section 701 certification. Call Dan directly on 07889 334849.
07889 334849