Bathroom circuits in Bath (BA1, BA2), Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Specialist bathroom electrician for Georgian, Victorian and Listed Bath properties, IP44+ Section 701 work, RCD-protected, NAPIT-certified. From £120 + VAT @ 20%.
Or WhatsApp: wa.me/447889334849
NAPIT
CHAS
City & GuildsBathroom circuits in Bath (BA1, BA2), Section 701 zone planning, IP44+ everywhere, every circuit 30mA RCD-protected, electric showers, heated towel rails, IP-rated lighting, shaver sockets and extractors. Specialist bathroom electrician for Georgian, Victorian and Listed Bath properties, IP44+ Section 701 work, RCD-protected, NAPIT-certified. From £120 + VAT @ 20%.
Full service detail and the eight-circuit kitchen brief on our parent Bathroom Electrics page.
Bath is a UNESCO World Heritage Georgian city, bathrooms are often retrofitted into former dressing rooms or bedroom alcoves, with thick stone external walls and shared chimney breasts. Section 701 zone planning is critical before drilling: every IP-rated fitting, shaver point and extractor needs to be placed against the actual zone diagram, not assumed.
Listed and conservation-zone properties need surface-mount or chase routes that don't damage original lath-and-plaster ceilings. We plan cable runs through joist voids and existing service voids wherever possible.
Heavy holiday-let and B&B market, bathroom electrics are inspected on every 5-yearly landlord EICR, so we issue full Minor Works or EIC certs that drop straight into the property file.
Sister city pages: EICR in Bath · Rewires in Bath
Final price depends on access, cable routes, existing wiring and whether the room is being refurbed at the same time. Survey is free; written quote is fixed. Read the disclaimer below the cards before assuming.
Yes. Listed bathrooms in Bath need careful zone planning and minimal-intervention cable routes. We work to BS 7671 Section 701 in full but coordinate routing with conservation requirements, typically running cables in existing service voids, behind skirting, or surface-clipped where chasing original stone is not permitted. Full LBC documentation supplied.
Single-circuit jobs (extractor, towel rail, shaver, mirror) are 1 day. A shower circuit replace is normally 1 day. A full bathroom rewire (extractor, lighting, shaver, towel rail, shower) is 2-3 days for first-fix and 1 day for second-fix after the tiling is in.
Section 701 of BS 7671 is the special-locations chapter for rooms with baths and showers. It defines Zones 0, 1 and 2 around the bath/shower and dictates IP rating and what fittings are permitted in each zone. Zone 0 is inside the bath itself (12V SELV only). Zone 1 is above the rim (IP65, 30mA RCD). Zone 2 is the area within 0.6m of zone 1 (IP44 minimum). Outside zones is 'general' but RCD protection is still required on every circuit serving the bathroom.
Free survey, fixed-price written quote, full BS 7671 Section 701 certification. Call Dan directly on 07889 334849.
07889 334849Same trusted DS Electrical service across our other Somerset coverage areas.