Electric shower install and circuit upgrade — BS 7671 Section 701 (special location: bathrooms), dedicated radial circuit sized for the shower kW, 6mm or 10mm cable depending on rating and run length, 30mA RCBO protection, ceiling-mounted pull-cord isolator. We fit Mira, Triton, Aqualisa and Bristan electric showers. Local cover for Bruton (BA10) and surrounding villages. From £320 + VAT @ 20%.
Or WhatsApp: wa.me/447889334849
NAPIT
CHAS
City & GuildsElectric shower install and circuit upgrade — BS 7671 Section 701 (special location: bathrooms), dedicated radial circuit sized for the shower kW, 6mm or 10mm cable depending on rating and run length, 30mA RCBO protection, ceiling-mounted pull-cord isolator. We fit Mira, Triton, Aqualisa and Bristan electric showers.
Full service detail and the installation specification on our parent Electric Shower Install page.
Bruton (BA10) has become a destination village thanks to Hauser & Wirth Somerset and a wave of high-end refurbishments. Period stone cottages on the High Street, Georgian houses around the Dovecote, and converted barns in the surrounding hills are typical — hot-tub, shower and immersion work here is invariably high-spec, design-led and needs a careful, low-impact installation.
Sister city pages: EICR in Bruton · Bathroom electrics in Bruton
Final price depends on access, cable routes, existing wiring and scope. Survey is free; written quote is fixed. Read the disclaimer below the cards before assuming.
Yes. We've worked on properties in Bruton, Castle Cary and Pitcombe where the architect or interior designer expects neat, low-profile, first-fix work with everything documented. We provide drawings, test certs, photos of buried cable runs and a clean handover pack.
Up to 8.5kW we use 6mm cable on a 32A breaker. From 9.5kW upwards (which is most modern showers) we use 10mm on a 40A breaker. Volt drop and run length matter too — for runs over 20m we'll often size up regardless. The shower manufacturer's manual sets the minimum, and we calculate the rest at survey.
BS 7671 Section 701 prohibits switches and sockets in Bathroom Zones 0, 1 and 2 (other than IP-rated specific products). A ceiling-mounted pull-cord is the standard way to isolate the shower without breaching zone rules. It's double-pole, located outside the danger zones, and lets you isolate the shower for cleaning or fault-finding without going to the consumer unit.
Free survey, fixed-price written quote, full BS 7671 certification. Call Dan directly on 07889 334849.