Immersion heater electrical install, fault-find and Economy 7 timer wiring — dedicated 16A radial circuit, double-pole switched fused connection unit at the airing cupboard, 30mA RCBO protection. We rewire dual-element tanks, fit Economy 7 timers, fault-find tripping breakers and replace burned-out switches and elements. Local cover for Frome (BA11) and surrounding villages. From £140 + VAT @ 20%.
Or WhatsApp: wa.me/447889334849
NAPIT
CHAS
City & GuildsImmersion heater electrical install, fault-find and Economy 7 timer wiring — dedicated 16A radial circuit, double-pole switched fused connection unit at the airing cupboard, 30mA RCBO protection. We rewire dual-element tanks, fit Economy 7 timers, fault-find tripping breakers and replace burned-out switches and elements.
Full service detail and the installation specification on our parent Immersion Heater Electrics page.
Frome's BA11 housing stock is mixed — Georgian townhouses on Catherine Hill and Trinity, Victorian terraces, ex-mill conversions and modern estates around Critchill and Mount. The mill conversions in particular present interesting challenges: high ceilings, exposed brick, original timber and bathrooms or hot-tubs squeezed into former industrial spaces.
Sister city pages: EICR in Frome · Bathroom electrics in Frome
Final price depends on access, cable routes, existing wiring and scope. Survey is free; written quote is fixed. Read the disclaimer below the cards before assuming.
Yes — we've done several in Frome. Mill conversions usually have exposed brick walls and timber floors, so cables either run in containment along beam lines or get fed through service voids. We always agree the route with the leaseholder and management company first if it's a shared building.
Almost always a failed immersion element — when the Incoloy element corrodes, water leaks into the heating core and goes to earth. The RCD trips because there's a real earth fault. We test insulation resistance with a Megger, confirm element failure, isolate the supply and quote a replacement element with parts and labour.
Yes if you have an Economy 7 meter and the tank has two elements (or a single element you're happy to use overnight only). We wire two FCUs — one for the off-peak bottom element on the Economy 7 circuit, one for a 'boost' top element on standard tariff. A timer switches the off-peak circuit during the cheap-rate window.
Free survey, fixed-price written quote, full BS 7671 certification. Call Dan directly on 07889 334849.
07889 334849